suspicious-wall-clock-elapsed
Referenceduration computed from wall-clock reads
suspicious · warning · stable · since 1.0 · fix: never · on by default
Unix.gettimeofday and Unix.time read the wall clock: NTP steps,
manual clock changes, and suspend/resume make it jump both ways.
Arithmetic that turns wall-clock reads into a duration — now +. timeout deadlines, now -. started elapsed — silently produces
negative or wildly inflated durations under a clock step: watchdogs
kill healthy children, retry loops spin or hang. A monotonic counter
(Mtime_clock, the project’s own clock module) is the remedy, and
choosing one is a dependency decision — no fix.
(* bad *) let deadline = Unix.gettimeofday () +. timeout in …(* good *) let deadline = Mtime.add_span (Mtime_clock.now ()) span in …Fires on float +./-. (and Float.add/Float.sub) applications
where either argument is directly a Unix.gettimeofday () or
Unix.time () call, anchored at the arithmetic expression. Storing the
function as a clock seam, passing a timestamp as data, scaling with
*., monotonic counter subtraction, and Sys.time (process CPU time,
monotone) deliberately do not fire. A wall-clock read that flows
through a let binding before the arithmetic is a recorded false
negative.